HF-01 Sediment Filter
2.5" HF type · Polypropylene sediment · 5 µm · Quick HF connection, 4/6 stems
Sealed sediment filter used in HF series reverse osmosis units and water purifiers. Its polypropylene media retains sand, rust, sediment and other suspended solids with a 5 µm rating.
- Nominal rating
- 5 µm
- Flow rate
- 2.85 L/min
- Service capacity
- 9,462 L or 1 year
- Temperature / pressure
- 5 - 42 °C / 2 - 7 bar
Stock code6-25-HF01-5
Overview
By retaining particles at the start of the system, it prevents clogging of the carbon filters and the reverse osmosis membrane and extends their service life. With inlet and outlet on the same end, it fits the HF connection head without tools.
Features
- 5 µm depth filtration with polypropylene
- Retains sand, rust and sediment at the start of the system
- Protects the carbon filters and membrane from clogging
- Inlet/outlet on one end; fits HF series units directly
- Sealed housing; no housing cleaning needed at replacement
- Change-month marking area on the label (1 - 12)
Applications
- HF series reverse osmosis (RO) units
- HF 3-piece and 5-piece filter sets
- Under-sink water purifiers
- Mains-fed (bottleless) water dispensers
- Office and small commercial treatment systems
Models and Stock Codes
| Stock Code | Model | Filter Media | Rating (µm) | Flow (L/min) | Capacity* (L) | A (mm) | B (mm) |
|---|---|---|---|---|---|---|---|
| 6-25-HF01-5 | HF-01 Sediment Filter | Polypropylene (PP) | 5 | 2.85 | 9462 | 290 | 66 |
A: Overall length (including connection stems) · B: Outer diameter. 2.5" HF-type cartridge; inlet and outlet (IN / OUT) are on the same end. Sealed (welded) housing; the filter cannot be opened and is replaced as a unit.
* Label value; 9,462 L or 1 year, whichever comes first. Actual capacity depends on water quality.
Technical Specifications
Operating Conditions
- Operating pressure
- 2 - 7 bar (29 - 102 psi)
- Operating temperature
- 5 - 42 °C (41 - 108 °F)
- Flow rate
- 2.85 L/min (171 l/h)
- Replacement interval
- 9,462 L or 1 year
Materials and Construction
- Filter media
- Polypropylene (PP)
- Filtration type
- Depth filtration, nominal
- Housing
- Plastic (typically PP), welded
- Connection
- Inlet/outlet on one end, 4/6 stems (Quick HF)
- Use
- Disposable, sealed
Installation and Replacement
- Shut off the unit's water supply and open the faucet to relieve pressure.
- Remove the used filter from the HF connection head; use the 3-95-HFSA removal tool if needed.
- Remove the protective caps from the new filter and push it fully home, observing the IN / OUT direction.
- Slowly reopen the water supply and check the connections for leaks.
- On first use, flush the line for a few minutes; mark the change month on the label.
The filter is disposable and cannot be opened or washed. Replace it after 9,462 litres or 1 year, whichever comes first; more frequent replacement may be needed with high-sediment water. Do not use with microbiologically unsafe water or water of unknown quality without disinfection.
Packaging
| Stock Code | Box Size (mm) | Pcs / Box | Box Weight | Boxes / Pallet | Pallet Size |
|---|---|---|---|---|---|
| 6-25-HF01-5 | 325 × 325 × 330 | 25 | 6.2 kg | 40 | 100 × 120 cm (ISO) |
Wholesale and OEM
Request a quote and lead time for this product
We quote distributors, installers and project contractors by stock code. Ask us about OEM and private label production as well.